i
ATTO Technology Inc. FastStream SC Installation and Operation Manual
Appendix A CLI Provides an ASCII-based Interface
The command line interface (CLI) uses ASCII commands typed while in CLI mode.
CAUTIONCAUTION
Do not use CLI unless you are directed to
by an ATTO technician.
Changing parameters may cause loss of
data and/or disruption to performance and
reliability of the FastStream.
The ExpressNAV Storage Manager is the
preferred method to operate and manage
the FastStream. Refer to
Using the
ExpressNAV Storage Manager
on page
39 for details.
The command line interface (CLI) is a set of ASCII-
based commands which perform configuration and
diagnostic tasks. You may use them through the
ExpressNAV Storage Manager Advanced CLI page
(refer to
Advanced CLI page
on page 35) or by using
the serial port interface or the Ethernet management
port (refer to
Interface Options
on page 39).
• CLI commands are context sensitive and
generally follow a standard format
[Get|Set] Command [Parameter1|Parameter2]
followed by the return or enter key.
• CLI commands are case insensitive: you may
type all upper or all lower case or a mixture.
Upper and lower case in this manual and the
help screen are for clarification only.
• Commands generally have three types of
operation: get, set and immediate.
• The get form returns the value of a parameter or
setting and is an informational command.
• Responses to get commands are followed by
Ready.
• The set form is an action that changes the value
of a parameter or configuration setting. It may
require a
SaveConfiguration command and a
restart of the system before it is implemented.
The restart can be accomplished as part of the
SaveConfiguration command or by using a
separate
FirmwareRestart command. A
number of set commands may be issued before
the
SaveConfiguration command.
• Responses to
set commands are either an error
message or
Ready. *. The asterisk indicates
you must use a
SaveConfiguration command
to finalize the
set command.
• Set commands which do not require a
SaveConfiguration command are immediately
executed.
Note
Using certain CLI commands during normal
operation can cause a performance drop.
Once command actions are complete,
performance should return to normal levels.
Exhibit A-1 Symbols, typefaces and abbreviations used to indicate functions and elements of the
command line interface used in this manual.
Symbol/Abbreviation Indicates
- A range (6 – 9 = 6, 7, 8, 9)
... Indicates optional repetition of the preceding item
[ ] Required entry
| Pick one of
< > Optional entry
BlockDevID Index designation of a block as found by using the BlockDevScan
command
EnclosureIndex Index designation of an enclosure found by using the SESIdentify
command
fl Fibre Channel LUN ID (0 <= fl <= 31)
fp Fibre Channel port number (1 <= fp <= 2)