24
Exhibit 4.0-4 Events triggering an E-mail message, severity level and explanation
Event
Severity
Level
Explanation
Aborted Command Warning A command has been aborted
Device Down Warning A target device has failed or become offline
Hardware Error Critical An unrecoverable target device failure
Medium Error Warning A command terminated with an error condition that may have been caused by a
flaw in the target device’s physical medium or its recorded data.
Temperature Critical Unit’s internal temperature has increased to at or above the maximum operating
temperature or decreased to at or below the minimum operating temperature
Temperature Warning Unit’s internal temperature has increased to at or within the unit’s maximum
operating temperature less the unit’s temperature warning offset or decreased to
at or within the unit’s minimum operating temperature plus the unit’s temperature
warning offset
Unit Power On Info The unit has been powered up
Voltage Critical A monitored nominal voltage level has increased or decreased beyond the
percentages listed below:
Level
......
VDDA (3.30V)
.......
VDDB (2.50V)
......
VDDC (1.50V)
.....
VDDD(1.35V)
Low
........ .......
5%
....................
4%
.......................
5%
..................
4.5%
High
...............
8%
....................
5%
......................
5%
.................
5%
Voltage Warning A monitored nominal voltage level has increased or decreased beyond the
percentages listed below:
Level
......
VDDA (3.30V)
.......
VDDB (2.50V)
......
VDDC (1.50V)
.....
VDDD(1.35V)
Low
........ .......
3%
....................
3%
.......................
3%
..................
3%
High
...............
5%
...................
3.5%
....................
3%
.........., .....
3%