Página 1

iPBridge 2700C/R/DInstallation and Operation Manual

Página 2 - ATTO Technology, Inc

5 ATTO Technology Inc. iPBridge Installation and Operation Manual 1.2 ATTO iPBridge 2700C physical componentsThe ATTO iPBridge 2700C is a 1-Gigabit E

Página 3 - Contents

6Mb/sec. A separate solidly lit green LED indicates an active link, blinking indicates activity and off shows no link is present.Ethernet management p

Página 4

7 ATTO Technology Inc. iPBridge Installation and Operation Manual 2 InstallationIf you have not already completed the instructions on the Quick Start

Página 5 - Manufacturer limited warranty

8Installing MS iSCSI Initiator for Windows1 Download the latest version of Microsoft® iSCSI Software Initiator from www.microsoft.com/downloads. Searc

Página 6

9 ATTO Technology Inc. iPBridge Installation and Operation Manual 3 Configure the iPBridgeTo configure the ATTO iPBridge, use ATTO ExpressNAV. Defaul

Página 7 - Possible storage

108 Click Next.9 Select the answer to the question Does your network support Jumbo Frames?10 Click Next.11 Set your administrator password.12 Click Ne

Página 8 - (see Exhibit 1.1-2

11 ATTO Technology Inc. iPBridge Installation and Operation Manual 3.1 Target managementStorage devices are mapped using the designations for the iSC

Página 9 - (see Exhibit 1.1-1):

123 Click on the Device Maps link of the default target. 4 Select the devices from the box on the right hand side of the screen and drag to the approp

Página 10 - 6-pin connection pinouts

13 ATTO Technology Inc. iPBridge Installation and Operation ManualExhibit 3.1-1 Target node configurations.

Página 11 - Ready/Fault:

14 3.2 iSCSI configurationYou may fine-tune the iPBridge using the ATTO ExpressNAV interface.Several special iPBridge features may be accessed using

Página 12 - 2 Installation

ATTO Technology, Inc.155 CrossPoint ParkwayAmherst, New York 14068 USAwww.attotech.comTel (716) 691-1999Fax (716) 691-9353 Sales support: sls@attotech

Página 13 - (supplied by ATTO)

15 ATTO Technology Inc. iPBridge Installation and Operation Manual 3.3 Optional changesDefault values, even if you have not used the ExpressWizard, a

Página 14 - 3 Configure the iPBridge

16Enhance performanceNoteIf you used ExpressWizard to set up your iPBridge, changing these parameters may interfere with ExpressWizard settings.Defaul

Página 15

17ATTO Technology Inc. FastStream 5300 Installation and Operation Manual 4 Remote system monitoringYou may set up the iPBridge to send notifications

Página 16 - 3.1 Target management

18Remote management6 From the drop-down box next to each trap address, select the level of severity for which you want each address to be notified: N

Página 17 - Multiple target nodes

19 ATTO Technology Inc. iPBridge Installation and Operation Manual 5 Updating firmwareSeveral processors control the flow of data in the ATTO iPBridg

Página 18

20 6 TroubleshootingIf it is clear that a particular component system is at fault in a problem situation, go directly to that component. If it is not

Página 19 - 3.2 iSCSI configuration

21 ATTO Technology Inc. iPBridge Installation and Operation Manual• a separate lighted green LED for each Fibre Channel port shows activity and an un

Página 20 - 3.3 Optional changes

22Check componentsUse this procedure to check system components. For more information on the commands used in this procedure, refer to CLI provides an

Página 21 - Enhance performance

23 ATTO Technology Inc. iPBridge Installation and Operation Manual5 Verify that each used Ethernet port on the iPBridge can be pinged from the desired

Página 22 - 4 Remote system monitoring

24same machine. Check with the vendors to make sure they are compatible. 2 Verify that the PC has the latest iSCSI driver as well as the required serv

Página 23 - Email notification

Contents 1 ATTO iPBridge provides storage options ...1Embedded software featuresConnectivity, infrastructure sol

Página 24 - 5 Updating firmware

25 ATTO Technology Inc. iPBridge Installation and Operation ManualAn un-accelerated NIC does not offload anything so the CPU must do much of the proce

Página 25 - 6 Troubleshooting

26MaxBurstLengthThe maximum data payload, in bytes, in a Data-In or a solicited Data-Out iSCSI sequence. A sequence consists of one or more consecutiv

Página 26

27 ATTO Technology Inc. iPBridge Installation and Operation Manual 7 Interface optionsAlternative methods to the ATTO ExpressNAV interface may be use

Página 27 - Check components

28• Flow Control: None• Terminal type: ASCII• Echo: off f. Click OK.4 After you connect to the iPBridge, start-up messages are displayed. These mes

Página 28

i ATTO Technology Inc. iPBridge Installation and Operation ManualAppendix A CLI provides an ASCII-based interfaceThe command line interface (CLI) use

Página 29 - Performance Issues

iiCLI error messagesThe following error messages may be returned by the Command line InterfaceERROR. Invalid Command. Type 'Help' for comman

Página 30

iii ATTO Technology Inc. iPBridge Installation and Operation ManualEmailNotify disabled set emailnotify enabledEmailNotifyAddress get emailnotifyaddre

Página 31 - Reset/restore factory default

ivPassword Password set password Ping ping mp1 192.42.155.155ReadOnlyPassword Password set readonlypasswordReadOnlyUsername user set readonlyusername

Página 32 - 7 Interface options

v ATTO Technology Inc. iPBridge Installation and Operation ManualAlphabetical CLI command explanationsAccessControlControls access on a target node. A

Página 33 - Using Telnet

viDisplayTraceLogDisplays the most recent page of trace log entries. The optional parameter n is the number of lines to be displayed as a single page

Página 34

3.3 Optional changes ...15Preliminary stepsModify passwordsSet up a VLAN: Virtual Loca

Página 35 - CAUTIONCAUTION

vii ATTO Technology Inc. iPBridge Installation and Operation ManualEmailUsernameConfigures the user name which authenticates the login to the SMTP Ema

Página 36

viiiFCHardRegulates Fibre Channel hard address assignment. When enabled, the unit tries to use its internal hard address as its address on the Fibre C

Página 37

ix ATTO Technology Inc. iPBridge Installation and Operation ManualIPGatewayControls the current default gateways used by any Ethernet ports on the iPB

Página 38

xiSCSIWANIPAddressSets or displays the IP address reported to an iSCSI initiator located outside the iPBridge LAN. If this iPBridge is behind a NAT ro

Página 39

xi ATTO Technology Inc. iPBridge Installation and Operation ManualReserve Reports the state of CLI reservation for the current CLI session. If the com

Página 40

xiiSNMPDumpMIB Displays the contents of the ATTO iPBridge private SNMP MIB to the current CLI session. For further assistance with SNMP, consult your

Página 41

xiii ATTO Technology Inc. iPBridge Installation and Operation ManualTraceLogFilterFilters data from specific unit ports when trace logging is enabled.

Página 42

xivAppendix B Safety standards and compliancesThe equipment described in this manual generates and uses radio frequency energy. If this equipment is

Página 43

xv ATTO Technology Inc. iPBridge Installation and Operation ManualApplication of Council Directive: 89/336/EECStandard(s) to which conformity is decla

Página 44

xviAppendix C Warranty informationManufacturer limited warrantyManufacturer warrants to the original purchaser of this product that it will be free f

Página 45

Appendix A CLI provides an ASCII-based interface ...iCLI error messagesCLI summaryAlphabetical CLI command explanationsAppend

Página 46

xvii ATTO Technology Inc. iPBridge Installation and Operation Manual

Página 47 - European Standards

1 ATTO Technology Inc. iPBridge Installation and Operation Manual 1 ATTO iPBridge provides storage optionsThe ATTO iPBridgeTM 2700C/R/D iSCSI to Fibr

Página 48

2SCSI Tape LibraryATTO iPBridge 27004-Gb FC SwitchPossible storageconfigurationsEthernetFibre ChannelSCSIembeddedATTO iPBridge1500/1550/2500ATTO Fibr

Página 49

3 ATTO Technology Inc. iPBridge Installation and Operation Manual 1.1 ATTO iPBridge 2700R/D physical componentsThe ATTO iPBridge 2700R/D is a 1-Gigab

Página 50

4From the front of the iPBridge (see Exhibit 1.1-1):Ready/Fault LED is lighted green indicates ready, lighted yellow shows a faulted condition, and of